Skip to main content

Table 1 Proportion of contact cultures with low, acceptable and high microbial burden before routine cleaning and/or disinfection, after routine cleaning and/or disinfection and after the use of the UV-C robot

From: The use of a UV-C disinfection robot in the routine cleaning process: a field study in an Academic hospital

 

ENT outpatient area

Oncology outpatient area

Low

Average

High

Low

Average

High

Before C&D

45.8% (11/24)

37.5% (9/24)

16.7% (4/24)

22.5% (9/40)

60.0% (24/40)

17.5% (7/40)

After C&D

79.2% (19/24)

20.8% (5/24)

0% (0/24)

32.5% (13/40)

62.5% (25/40)

5.0% (2/40)

After C&D + UV-C

100% (24/24)

0% (0/24)

0% (0/24)

95.0% (38/40)

5.0% (2/40)

0% (0/40)

  1. C&D cleaning and disinfection, UV-C ultraviolet C; low = 0–3 CFUs/24 cm2, average = 4–50 CFUs/24 cm2, high > 50 CFUs/24 cm2